Troubleshooting Common Issues with White Rodgers 1361 Zone Valves

White Rodgers 1361 zone valves are commonly used in heating systems to control the flow of hot water to different zones in a building. These valves are known for their reliability and durability, but like any mechanical device, they can sometimes experience issues that require troubleshooting. In this article, we will discuss some common problems that can occur with White Rodgers 1361 zone valves and how to address them.

One of the most common issues with zone valves is a failure to open or close properly. This can be caused by a number of factors, including a faulty motor, a stuck valve stem, or a blockage in the valve body. If you notice that a zone valve is not opening or closing when it should, the first step is to check the power supply to the valve. Make sure that the valve is receiving power and that the wiring is intact. If the power supply is not the issue, you may need to inspect the valve itself for any visible signs of damage or obstruction.

Another common problem with zone valves is a leaking valve body. This can be caused by a worn or damaged seal, a loose connection, or a cracked valve body. If you notice water leaking from a zone valve, it is important to address the issue promptly to prevent damage to the surrounding area. Start by checking the connections to the valve to ensure that they are tight and secure. If the leak persists, you may need to replace the seal or the entire valve body.

Model AFC2-LCD AFC2-LED
Working Position Filter->Back wash 1->Back wash 2-> Fast rinse -> Filter\\u00a0
Regeneration mode Automatic\\u00a0 Automatic\\u00a0
Time by day :0-99days Time by day :0-99days
Time by hours:0-99 hours Time by hours:0-99 hours
In (inlet of valve) 1/2”F 1/2”F
I1(inlet of first filter) 1/2”F 1/2”F
I2(inlet of second filter) 1/2”F 1/2”F
Drain 1/2”M 1/2”M
D1( Drain of first filter) 1/2”M 1/2”M
D2(Drain of second filter) 1/2”M 1/2”M
Water capacity\\u00a0 2m3/h 2m3/h
Working pressure 0.15-0.6Mpa
Power Supply\\u00a0 AC100-240V/ 50-60Hz \\u00a0 \\u00a0 \\u00a0/ \\u00a0 \\u00a0DC12V-1.5A

In some cases, a zone valve may become noisy or make strange sounds when it is operating. This can be caused by a number of factors, including air trapped in the valve body, a loose motor, or a worn-out bearing. If you hear unusual noises coming from a zone valve, it is important to investigate the issue to prevent further damage. Start by bleeding the air out of the valve body to see if that resolves the problem. If the noise persists, you may need to inspect the motor and Bearings for any signs of wear or damage.


One of the most frustrating issues with zone valves is when they fail to respond to the thermostat. This can be caused by a faulty thermostat, a wiring issue, or a malfunctioning zone valve. If you are experiencing problems with a zone valve not responding to the thermostat, start by checking the thermostat settings and wiring to ensure that everything is in working order. If the thermostat is functioning properly, you may need to inspect the zone valve for any signs of damage or malfunction.

In conclusion, White Rodgers 1361 zone valves are reliable and durable components of heating systems, but they can sometimes experience issues that require troubleshooting. By following the steps outlined in this article, you can address common problems with zone valves and ensure that your heating system continues to operate efficiently. If you are unable to resolve the issue on your own, it is always best to consult a professional technician for assistance.